IdeaBeam

Samsung Galaxy M02s 64GB

Saleae logic pro 16 clone. 4: 140: July 17, 2024 .


Saleae logic pro 16 clone I went through the process of obtaining the firmware file and get the Neither here, nor there, but consider the fact that you can buy an oscilloscope like the Siglent SDS1104X-E for, let's call it $500, add the 16-channel digital signal analyzer + license for How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. The input pins on the new Saleae Logic devices (Logic 4, Logic 8, Logic Pro 8 and Logic Pro 16) have protection for signals within -25. Thank you for your help I use one of the cheap Chinese analyzers that, from what I can tell, uses similar hardware as the Saleae Logic 8. 2nd and 3rd nights the capture stopped and I have several (4-5) new blank session The Logic 2 software has the ability to decode a variety of protocols, including SPI, I2C, serial, 1-Wire, CAN, I2S/PCM, and many more! To create your own protocol analyzer, refer to our . Yes. 25MS/s and 1. As explained in the windows Continue reading USBee AX Pro reprogramming → Note that Saleae devices can currently only decode low-speed (1. I recently purchased the Saleae Logic Pro 16, and it is an absolute joy compared to the scope. 5Mbps) and full-speed (12Mbps) USB traffic. 0 Host Controller Cards; Device Settings Configuration Tips; All Saleae Logic devices will work properly when connected to a USB 3. Demonstrates how to use Python to automate the Saleae Logic2 software. Logic SDK allows you to make your own analyzer plug-in. A logic analyzer is a debugging tool used to record and view digital signals. , one bit at a time). It is part of the second-generation Saleae Logic series, which consists of the Logic 4, Logic 8, Logic Pro 8 and Logic Pro 16. Stars. The Saleae Logic produces data at a fixed rate and can't tolerate periodic delays between read requests because the the USB line during data capture. This may work for most applications. Hello everyone! First of all, I hope I picked the right subforum, I was not entirely sure. 21 Welcome to the 2. In this case, you must use the GUID for the specific model of unit you have purchased, as it is specified in the Saleae *. A quick overview of the cheap clone of Saleae USB logic analyzer 24 MHz 8 ch. Wikipedia. 16 channel variant for 300$ seems reasonable, but I am considering 32 channel version, since the specs are the same for 16 and 32 channel versions. Is there any chance to make it working? Thanks in advance! You need the firmware for the Cypress IC inside your device. Software. The Logic 2 software allows exporting of the entire Data Table, which can include entries from all of your added analyzers. Priced at $399, it’s an 8 channel logic analyzer with a max sampling rate of 500 Megasamples/sec, though when using all 8 channels the max sampling rate is reduced to 100 MS/sec. EEVblog Electronics Community Forum. Driver Install. The analog input on Logic 4 and Logic 8 is limited to +0V ็Hello, I was wondering whether if Saleae Logic Pro 16 LA worth it. (I don't know if it still does. 40 to sanity-check that it’s not an 1. Both are streaming logic analyzers. Click the Analyzers panel button and then the + button to add a protocol analyzer. The Gen 1 accessories are compatible with these devices: Original Logic (discontinued) Это видео – самая подробная инструкция о работе в ПО Saleae Logic Software 1. The case requires a Torx T5 screwdriver to open. Wire Harness (Gen 2 Version) A 2x4 wire harness is used by Logic 4, Logic 8, Logic Pro 8, and Logic Pro 16, which are our 2nd-generation logic analyzers. 0 to push all that sample #boring_logic A 16-channel logic analyzer based on CY7C68013A MCU. Hi Saleae Team. The only older version you should consider using is if you are on Linux and the latest software is not working (as in the case of CentOs 6. After some searching I find a few other mentions of this on the forum, but little discussion on how to make it work well. User Guide. I just didn't want to buy a clone and rip off their software, so If the drivers are installed properly, you should see Saleae Logic X USB Logic Analyzer in Device Manager, where "X" is the specific product version (4, 8, Pro 8, Pro 16). 2. If "unidentified device" or "Westbridge" appears, then there is a Saleae Logic Pro 8 is a 16 channel logic analyzer with state-of-art software. User Guide Previous Community Shared Analyzers Next Logic Analyzer Tutorial. 14, the team has been focusing primarily on still unreleased functionality. Hello, I’m trying to decode an RS-485 bus. The Saleae products support decoding for over 20 different protocols. 0 cable. Looping mode, with 0. The example image below shows a 4-bit data bus and a clock signal, which requires 5 channels. The PCB is marked "Saleae16 v4. The Saleae Logic Pro 16 is a trusted companion that earns its place on the workbench. Saleae Logic Pro 16 capabilities for a task. Learning Portal Example Projects. I assumed that either we can group the digital lanes into Download Logic 2 Software for advanced logic analysis with Saleae Logic Analyzers. The PCBs get a closeup inspecti The Logic Pro 8 is the second from the top in Saleae’s product lineup, which also includes the Logic 4, Logic 8, and Logic Pro 16. ). @alex Sorry for the trouble with that!. Topics. Readme Activity. 0 port to get the bandwidth and I'm assuming there's no buffer in it. " Saleae Output Parser. 8 ~ 5. Though while many software packages could support this device as a 16-channel logic analyzer, only 8-channels are buffered and brought out. Parameters: 8 channel logic analysis 1. The WayEngineer Saleae16 is a USB-based, 16-channel logic analyzer with 100/50/32/16MHz sampling rate (at 3/6/9/16 enabled channels). More In this episode Shahriar takes a look inside the "Logic", "Logic16" and USBee SX which were reviewed in the previous episode. And then for LA purposes, it's severely limited. g. Not talking with USB correctly has also had other side effects - like not working with an ST-LINK debugger (not the issue here - the Logic Pro is the ONLY device plugged into my computer other than the power cord). 0) => not found. When voting for it, you can refer to Mark's comment to -USBee logic analyzer-Saleae logic analyzer. Navigating the Software. Every month, over 20,000 professionals and enthusiasts, from Arduino hobbyists to aerospace engineers, rely on Logic to debug and understand their electrical designs. 0 port, a USB 3. It will filter the data further before down sampling so data sampled at lower The same problems on windows 11 insider preview (latest update) - tried several versions, incl. Is it less than 500mA ? The Saleae Logic Pro 16 is a powerful logic analyzer that lets you record and display signals in your circuit, so you can debug it fast. 0 cable, capture settings will not persist when closing and re-opening the software. It is a clone of the Saleae Logic. I haven't been able to get pulseview to work with my clone (exact same packaging but not so sure under the covers). In this episode Shahriar takes a look inside the "Logic", "Logic16" and USBee SX which were reviewed in the previous episode. The original Logic's inputs float at about 2. e. This forum is mostly expert users, so I thought you View and Download Saleae Logic user manual online. I can see that the sampling rates below 781. Top Resources. It is not clear what what could be wrong or how I need to configure it? Saleae Support. Here are the settings: I lock my computer, but do not shutdown or log out. 3 5. Pinguino 18F2550 Dev Board. Does one of you know more about this? The Saleae Logic16 is a USB-based, 16-channel logic analyzer with 100/50/32/16MHz sampling rate (at 3/6/9/16 enabled channels). 2 watching. The Logic Pro 8 uses USB 3. Sharing a video using the Logic Pro 16 for power sequencing verification. Download. Before this point, the Please note that when connecting our USB 3. Another user reported a similar issue on NixOS, and installing libxcrypt seemed to solve it for them. The newer products (Logic 4, Logic 8, Logic Pro 8, and Logic Pro 16) have significantly larger device side stream buffers and should The SPI analyzer included in the Saleae Logic software supports this case. The key parameters in the main VI are the Anaconda setings and the Saleae Logic First, if you are troubleshooting Logic Pro 8 or Logic Pro 16, please check the link below to double check its connection to your PC via USB 3. Each of these logic analyzers is useful in different situations. /Logic-1. If "unidentified device" or "Westbridge" appears, then there is a problem with the Saleae driver. 5 %µµµµ 1 0 obj >>> endobj 2 0 obj > endobj 3 0 obj >/XObject >/ProcSet[/PDF/Text/ImageB/ImageC/ImageI] >>/Annots[ 21 0 R] /MediaBox[ 0 0 612 792 The Saleae Logic Pro 16USB Logic Analyzer is a channel logic analyzer with each input dual purposed for analog data recording. Supported Operating Systems. The original Logic could record signals at 24 MSPS on 8 channels and supported IO voltages between 2. Sorry for the confusion that caused. " Exporting Raw Data. This is a clone of the Saleae Logic16. Logic 2. Crystal: 24MHz See more The Noname XL-LOGIC16-100M is a USB-based, 16-channel logic analyzer with up to 100MHz sampling rate. USB interface chip: Cypress CY7C68013A 3. It operates by sampling a There is no need to manage downloading firmware updates to Saleae Logic products. So my question is: is it possible to make 125 kS/s available in Logic 2, too Saelae is one of a multitude of companies that make similar hardware based on the original FX2 dev board. When FX2 chips came out the manufacturer (Altera) had a demo logic analyzer implemented in software for it - the board uploads its firmware when its started. Thank you for your help The new Saleae Logic products (Logic 4, Logic 8, Logic Pro 8, Logic Pro 16) can be used to read and decode RS-232, RS-485, and RS-422 data up to +/- 25V. bitstream saved 149516 bytes to saleae-logic16-fpga-33. an interrupt pin, to permit drawing the returned AnalyzerFrame() with the end time of interrupt occurring. 4 volts, with over 100 K ohms of pull-up resistance, producing a very small pull-up effect. You may receive a warning notification from The Saleae Logic16 is a USB-based, 16-channel logic analyzer with 100/50/32/16MHz sampling rate (at 3/6/9/16 enabled channels). In other words, worse case. 29 issue: I connected my logic8 to my Debian machine, and booted up Logic 1. Watchers. 21 release of Logic! Much like the last release, 2. If you notice a problem with the voltage threshold on Connecting to higher voltage signals with the new Logic 4, Logic 8, Logic Pro 8, or the Logic Pro 16. ARMFLY Mini-Logic 2: 08a9:0014 Clone (AX-Pro w/o scope) 8 56LTXC (QFN) ? 100 Ω Atmel ATML920 24C02N SU27 D Eval board / Clone (Logic) 8/16 56PVXC (SSOP) none none Shenzhen First-Rank Technology T24C128A 100% MCU123 Saleae Logic clone: 0925:3881 Clone (Logic) 8 56PVC (SSOP) NXP 74HC245 100 Ω Atmel AT24C02 The Noname XL-LOGIC16-100M is a USB-based, 16-channel logic analyzer with up to 100MHz sampling rate. the 16 bit version has a cpld on board to multiplex the 16 bit inot an 8 bit stream for the cypress chip. It’s perfectly safe to connect any signal up to this range directly to its inputs. Protocol Analyzers. Address. All hardware files are located in 'hardware' directry, including shematic, PCB, gerber files, and BOM. com which is very similar to a Saleae Logic. That said, quite a bit has changed under the hood. Is there a way to do this. Connecting the Logic Analyzer If connecting Logic Pro 8 or Logic Pro 16 to a USB 2. Saleae Logic Pro 8 quick teardown - Page 1. The Saleae does have analogue ports and the Kingst has none. They do not support a hardware analog zoom like oscilloscopes do. See Saleae Logic for the predecessor product of the Saleae Logic16. 0 V level input 24 Mbps sampling Storage depth depends on physical memory, general PC 10 M ~ 50 M In the Logic 1 software the 125 kS/s was an ideal choice, but now I have to use the 781. But also useful is to have an extra input pin, i. 25 kS/s in Logic 2, which is a waste of RAM compared to Logic 1’s 125 kS/s sampling rate. 3V voltage regulator: Advanced Monolithic Systems AMS1117-3. The Saleae Logic Pro 8 USB Logic Analyzer is an 8 channel logic analyzer with each input dual purposed for analog data recording. Legacy Software Logic Analyzer Tutorial. However I see no capability to display a bus and the parallel decode option requires a We don’t have a way to read the raw digital states in the python HLA API at this time. I am trying to understand the technical limitations of Saleae Logic’s analog inputs. Sync. as it is capturing it cannot process the data. Firmware Updates. Logic Pro 8/16 - Voltage Threshold Setting in the Logic 2 How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. Depending on the number of channels you use, the Logic 8 can sample up to 10 MS/s (bandwidth of 1 MHz). More We offer discounts for: * Students * Electronics Enthusiasts (non-commercial use) * Small Startups * Independent Contractors Standard Pricing Student Pricing Enthusiast Pricing Startup/Contractor Pricing Logic 8 $499 $249 $249 $369 Logic Pro 8 $999 * * $849 Logic Pro 16 $1499 * * $1349 (*) contact us for details All non-standard prices require a discount code. Logic Pro 8, and Logic Pro 16, should work properly. Setup. See WayEngineer Saleae16/Info for more details (such Connect one or more cable harnesses to the Saleae Logic Analyzer. 19. 1 gen 1 port, 90% of my work can be done with this $10 Saleae clones. USB Bit Whacker. Requirements. A new value is written to the port when the state changes. md at main · anno73/Saleae-Logic16-Clone You can add 4x2 male headers to your PCB and use the Saleae accessory cable "Logic-to-2x4 Header (Gen 2)" to connect any of the current Saleae logic analyzers to your circuit. The DSLogic Plus works with its own software for multiple platforms and also with 16 channels. 25 kS/s are different in Logic 1 and Logic 2. 0-based, 16-channel logic analyzer with 500/100MHz sampling rate (at 4/16 enabled channels) and analog sampling support on all 16 channels. Normal triggering is not working, so the only way is to stream raw data from de logic pro 24/7 and save a chink of data when the problem occurs. Reply reply Hey Saleae! I’ve been ogling at the pro versions of your logic analyzers for a few months now. The device I am trying to monitor is an MSD, I have restricted it to Full Speed to try and be able to monitor it using Saleae Support. This is because the triggering depends on 2 analog inputs. Search Ctrl + K. If you have a Linux, continue to read. « Reply #16 on: One useful feature of your Saleae Logic Analyzer is its ability to measure analog signals (from 0 to 5 V). To export the Data Table, click the 3 dots to the right of "Data," then click "Export Table. Wide system support Win, Mac, Linux. The Original Logic is the most sensitive to this issue. time/voltage columns). Logic 4 has a maximum digital bandwidth of 3 MHz, and USB full speed requires a digital bandwidth of at least 12. Product Summary. Can i get the . Saleae Support. 3. And I use the terminal to log the data in hex format. At the moment I am storing the capture to a . 0 port, please read the article below. Its large box provides ample space to store everything, making it easy to transport the Logic Pro 16 whenever travel is necessary. The device can be safely used for normal operation with signals in this range. While the FAQ says it can’t be done, I’ve been using two LogicPro 16’s on a windows 11 computer using two instances of Logic 2. However, I just did a quick test, and I can confirm the above does not work on my end - downloaded 1. I have used Logic 1 for a couple of years and built up an automated test setup where I use a Pro 8 device for nightly verification of a stepper motor control. 4: 140: July 17, 2024 We offer discounts for: * Students * Electronics Enthusiasts (non-commercial use) * Small Startups * Independent Contractors Standard Pricing Student Pricing Enthusiast Pricing Startup/Contractor Pricing Logic 8 $499 $249 $249 $369 Logic Pro 8 $999 * * $849 Logic Pro 16 $1499 * * $1349 (*) contact us for details All non-standard prices require a discount code. The trick is to get the second Logic device to connect I have a logic 16 device and am using logic 2. fw saved 149516 bytes to saleae-logic16-fpga-18. See WayEngineer Saleae16/Info for more details (such as How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. With easy USB connection and software installation, it's perfect for professional or experienced home users. This is something we want to fix! If you have a moment, we would appreciate if you add your interested to the feature suggestion here: High-level analyzer: combine data from multiple sources - Logic 2 - Ideas and Feature Requests - Saleae. com Logic Analyzers from Saleae - #1 with Professional Engineers. Relevant GUIDs: Logic 8 “{03C61D2D-8A38-4FD3-9E60-1BCAA5FA28C1}” Logic Pro 8 “{DDB1D63F-0ECF-4E86-94E7-ADB4C765E352}” Logic Pro 16 “{DDB1D63F-0ECF-4E86-94E7-ADB4C765E353}” I've heard that the Saleae clone works with the Saleae original software, for a fraction of the price. Is possible to log the data in the Terminal for a long time for exmple two days. It’s a great looking platform, and the new Logic 2 Alpha software looks just fantastic with the live view feature and embedded console. %PDF-1. Yeah. Be wary of the Saleae Logic 16 clones. I've purchased a genuine logic-16, so I don't feel that bad about hacking a Chinese clone to emulate the cheaper version. I assumed that either we can group the digital lanes into a bus, or else use the parallel decode option. A Free & Open Forum For Electronics Enthusiasts & Professionals I was anxious to try out the upper 8 channels on my Pro-16, which require USB 3. . 16 Micro-Gripper Hooks • Saleae Carrying Case, USB 3. 21 Download Links Windows Linux MacOS [x86_64] MacOS [Apple Silicon] 2. Just note that hidden channels will still sample data and consume bandwidth during recordings. Now, the price is quite high for the 32, so is it really worth it? SAL-00115 Logic Pro 16 Black SAL-00116 Logic Pro 16 Red As well as non-Pro Logic 8s, but mostly Pro 16s. I was thinking about DreamSourceLab's DSLogic Pro series. Note that achieving the highest sample rates requires low USB latency; this may not be achievable on all computers. 6 By mcupro". I can return AnazlyerFrame() start and end times based on the input analyzer frame passed to the decode() function. Saleae Support; Orders & Shipping Getting Started. 0), and I now cringe when having to switch back to a bench oscilloscope. If you run into any issues or have any feedback for us, please . While there are many advantages to providing the SDK in this format, implementation of a custom protocol will probably take an Hello, we purchased this logic pro 16 intending to log the value of an 8 bit microcontroller port over time. This is a powerful logic analyzer in a very small anodized aluminum package from Saleae Logic. 00V to +25. I’m seeing input topping out at ~10. It works very well on Linux with Sigrok/fx2lafw and PulseView. Performance may improve with the removal of other USB devices, using a different USB host controller, or increasing the software's process priority. 5% Real 16 port Saleae LA. 2 pro with 8 channels and it works very well. USB Tutorial. With USB connectivity, you can analyze up to 16 digital/analog waveforms and timing information on your I2C, SPI, serial, and digital IO lines with ease. 04 (Lenovo), the other using Pop!_OS 20. You can then run the Logic binary directly from there. All four of the new Saleae devices include over-voltage protection to +/- 25 volts. See Noname Saleae In this case, you must use the GUID for the specific model of unit you have purchased, as it is specified in the Saleae *. 5 MHz. In Hi there I am using Saleae Logic 8 with Automation Python API to capture one Analog Channel for 200ms and I was wondering if I can directly use the capture inside python, for example as a numpy array (e. Sigrok is an opensource set of tools to deal with tools such as oscilloscope The Saleae Logic Pro 16 is a USB 3. This calibration data is not stored on the device. inf file included with our driver. Our older Logic products (Original Logic, Logic16) have a 0V to 5V absolute maximum range. 5 6. 1 Download Links Check out the Saleae Logic 2 Extension Marketplace! Read more about the Marketplace on the Saleae blog! What’s New Added a “reset to default” button to the presets manager Improvements When saving HLA settings, restart the analyzer if there was a change Updated the terminal library to the latest Reset analog zoom & pan If you are using one of the newer products (Logic 4, Logic 8, Logic Pro 8, Logic Pro 16), you will not be able to use older versions of the software. From Arduino projects to spacecraft control systems, over 20,000 professionals and enthusiasts use Logic each month to debug and understand their electrical designs. We should make this clear in the software. Share this: Reddit; Twitter; Facebook; More; saleae-logic-clone-8 (Custom) Leave a Open Device Manager. CRC. You can really get spoiled with a ‘capture everything and just post-process it’ Connect one or more cable harnesses to the Saleae Logic Analyzer. Simply letting Logic capture for 15-30 minutes will cause the UI to become unresponsive, as well as stop displaying new data. Available Sampling Rates 2. . Strange to think 5 years ago I was looking at my Saleae as a “poor mans LA”, and now I regard it as an essential tool. Note that each cable harness has an arrow on the top of the connector. The framework is very flexible . An exact number is not needed. FEATURES • Deep Sample Buffers • Highly Portable, USB Attached • 24 Included Protocol Analyzers How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. Last updated 3 years ago. ) It works just fine with sigrok (an alternative software), so if your need is digital only, 24 MHz, 8-channel, it's a $20 prospect to try If you are using one of the newer products (Logic 4, Logic 8, Logic Pro 8, Logic Pro 16), you will not be able to use older versions of the software. The serial analyzer in the Saleae software is flexible, but it's ultimately designed to only decode serial data that on the same note. - Actions · anno73/Saleae-Logic16-Clone . Contents. 4. the last one is 2. A copy from the terminal: read to 0x40 ack data: 0x61 0x48 0x66 Hi there I am using Saleae Logic 8 with Automation Python API to capture one Analog Channel for 200ms and I was wondering if I can directly use the capture inside python, for example as a numpy array (e. Four digital, two analog channels turned on. AppImage --appimage-extract, which will dump the contents to a new directory called squashfs. My clone Saleae Logic 16 just was not fast enough for some of my projects but worked really well within its limits and with the Saleae software. I use 1 analog and 4 digital channels, where the digital channels need very high sample rates (at least 50 MS/s) - Oh, I see what you mean. So why would you buy the Saleae instead of the Rigol (Rigol has more features beyond logic analyzer and has similar specs to the Saleae). The issue seems to be as follows: libcrypt. See WayEngineer Saleae16/Info for more details (such as lsusb -v output) about the device. Has anyone encountered this issue and know of a workaround? Regards, Ian Saleae Support. In that case, you should try either the compatibility release of the latest version or No. Enhance your debugging and data analysis with user-friendly features, real-time updates, and extensive protocol support. The Saleae Protocol Analyzer SDK lets you make your own custom protocol analyzers. FTDI Breakout. It seems to have 3 firmware images, and depending on the jumpers it looks like an Altera Byte Blaster, a Saleae Logic analyzer, The issue here is that the clone here can now use the Saleae or USBee logic software which is a substantial cost. Logic Pro 8 and Logic Pro 16 can only record signals that fast on 4 channels, and 4-channel ESPI uses 8 channels (reset, CS, clock, alert, 4xdata). Supports Logic 8, Logic Pro 8, and Logic Pro 16. The new Logic 2 Automation API is now available, starting in Logic 2. Reply reply I have the basic Saleae logic 8 at home and the Logic Pro 16 at work. The new software identifies it correctly as a 16 port but when I try to the port nine to 16, the software does not allow it. Capturing at 6. I’m hoping your’re able to reproduce this issue as well. Find and fix vulnerabilities Actions Hi All, From what I have heard, the Saleae logic Analyzers a very good, the PC software is very useful for protocol analysis. 38. It operates by The Logic 2 software allows exporting of the entire Data Table, which can include entries from all of your added analyzers. To use it with the Saleae software, the VID/PID need to be reprogrammed. Skip to content. The only older version you should consider using is if you are on Linux and the latest software They use altium to make their boards and schematics. 04 (System76) both using a Logic Pro 16. I am interested to understand how the wide signal input range for logic analyzers like the Saleae Logic Pro 16 [1] or DreamSourceLab DSLogic Plus [2] has been realized. Looking Hello everyone! First of all, I hope I picked the right subforum, I was not entirely sure. keep in mind that this is essentially a streamer. A scope is helpful, but it's more pricey to the logic clones out there and it's a bit more to setup. 業界をリードするプロフェッショナル向け16チャンネルロジックアナライザーで、電子回路のプロフェッショナルデバッグ、プロトコル解析、および電源シーケンシングをサポートします。Logic Pro 16ハードウェア、アクティブな技術 I am trying to catch a hard problem to reproduce and am leaving our product with a Logic 8 Pro connected and logging overnight. Orders & Shipping Getting Started. Powered by GitBook I have a problem with a system that only occurs 1 time a day. Exporting the Data Table; Exporting Raw Data; Exporting Analyzer Results; Community Shared Export File Saleae Logic2 Analog filtering technical details? - #17 by Sebastian for a script that reduces filtering (increases analog bandwidth). I got my LA for 40 bucks off ebay and it's 16 channels. However, you will need to use a device with sufficient bandwidth to record the original signal. 40-Linux. 3. Frankly, I bought a SX clome from china at one point, and the software was so terrible I reprogrammed the EEPROM to make it enumerate as a Saleae Logic-8. Home Download User Forum Contact Us. Decoding the Data. Hi, QQ. As such, it can function as an oscilloscope with up to 8 channels (for the Logic 8 and Logic Pro 8) or 16 channels (for the Logic Pro 16). " You will be greeted You can set the logic analyzer to begin recording only when it sees a particular edge or pulse by selecting Trigger from within the Capture Settings panel. Sign in Product GitHub Copilot. 00 + VAT = £982. 0, so I ordered a USB 3. 6 For the first time I am trying to monitor/analyze USB data. Saleae already has a lot of my money. 0 card and then I bumped into this popup: Quote. Relevant GUIDs: Logic 8 “{03C61D2D-8A38-4FD3-9E60-1BCAA5FA28C1}” Logic Pro 8 “{DDB1D63F-0ECF-4E86-94E7-ADB4C765E352}” Logic Pro 16 “{DDB1D63F-0ECF-4E86-94E7-ADB4C765E353}” I used the logic decoding functionality of my Rigol DS1054Z for years, and the experience is mediocre and cumbersome. But after 7 minutes the data in the terminal are overrided and I can not used it. x). I think the no-name device is a clone of the Logic 16 (not to be confused with the much more capable Logic Pro 16). It is labelled and sold as a Saleae Logic16 clone, and comes with "modified" The WayEngineer Saleae16 is a USB-based, 16-channel logic analyzer with 100/50/32/16MHz sampling rate (at 3/6/9/16 enabled channels). The Logic software downloads the firmware to the device every time it is connected to the PC as shown in the image below. This is a clone of the Saleae Logic16 . The Saleae Logic software includes a protocol decoder to read clocked (synchronous) parallel bus data. The Salea device only seems to support direct mode, so you need a USB 3. The Saleae Logic Pro 16 is a powerful logic analyzer that allows you to record and display signals in your circuit, enabling fast and efficient debugging. 5 How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. 7 stars. R0A is an alpha version, and R01 is the final release. The PCBs get a closeup inspecti Hello everyone, I use the logic analyzer 2. For more information about the differences between the Saleae products and oscilloscopes, see this article: For more information about the analog resolution of the Saleae products, see this article: The original Logic and Logic16 were discontinued in mid-2014 when they were replaced with a new line of products—Logic 4, Logic 8, Logic Pro 8, and Logic Pro 16. Safety & Warranty. I then continued to monitor the bus using my pro 16 which sometimes you see the correct data over the bus and then sometimes you see corrupted data. In sigrok, we use the open-source fx2lafw firmware for this logic analyzer. Our 4x2 connectors are comprised of: Logic Pro 16. The DSLogic Plus works with The original Logic is the only Saleae device to have internally pulled up inputs. 40? I assume you mean a non-Appimage Linux zip release? You can extract the appimage with . Please note that the windows driver update check will NOT update USB 3. all post processing is done on the pc. If you shop around it is possible to get a Rigol MSO5000 series scope for the same price. 10, также в видео уделено не мало One using Pop!_OS 21. - Saleae-Logic16-Clone/README. 0! You can find more information on this on our . 3V Thanks Dean saleae. - Actions · anno73/Saleae-Logic16-Clone. The 1st Generation (Original Logic and Logic16) do not require any form of calibration. In these cases, please follow the instructions in the support article The Saleae Logic Pro 16 is a USB 3. I assume you own the Gen1 Original Logic. However, the master on this bus has a 2V offset compared to the slave, so I can only capture the RX messages from the slave. The overview includes explanation about the software (Sigrok) and the hardware. To export raw data from your capture, click the Options button at the bottom right of the software, then click "Export Raw Data. 13 to collect data simultaneously from the two devices. The analyzer supports between 1 and 16 bits of data bus, although realistically, only 15 bits are possible due to the relance of a clock signal taking up one channel. For instance, Logic 4 simply does not have the bandwidth required to capture and decode USB full speed. In this case, we recommend saving capture setting presets as described below. Key The Saleae Logic Pro 8 USB logic Analyzer is an 8 channel logic analyzer with each input duel purposed for analog data recording. I have a Logic Pro 16 connected to the D+ side of the bus with the Analyzer set to Async Serial (see image for settings). USB Brief Tutorial. 0. The unlabeled black wires are ground (GND), and the signal wires are labeled 0-7 (repeated if you have the Logic Pro 16). Using Logic. Navigation Menu Toggle navigation. Therefore, neither product can be used to measure signals outside of this range. How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. 40. This Logic Analyzer is a very nice clone of the 8-Channel 24 MHz Saleae unit. 15 through 2. Once the data has been collected, you can navigate directly to the trigger point by clicking Hello everyone, I use the logic analyzer 2. See Noname XL-LOGIC16-100M/Info for more details (such as lsusb -v output) about the device. What Logic Decodes. Looking straight at the ports of the analyzer, the top row of pins are labeled 0-7. I also did not pay much attention to the master as I never had to doubt what Saleae displayed. Write better code with AI Security. 5V voltage regulator: Advanced Monolithic Systems AMS1117-1. See Saleae Logic and Saleae Logic16 for the predecessor products. Hi Paul, Thanks for your answers! Let's start with the good news, I think you are right with regards to the second part, I have been fiddling around with short and long cables and may have moved to a new USB port on a HUB, when I stick to the same port each time it seems to "remember" it's driver. We’ve seen a few international teams using the hardware in this way and I wanted to share. Saleae is common and widely used, but they have ridiculous prices these days. Several companies implemented hardware based on that design, using pretty colors, nice grabbers, ็Hello, I was wondering whether if Saleae Logic Pro 16 LA worth it. The procedure is well explained here if you have a windows. I have a Logic Pro 8. it just samples the state of the 8 input pins as fast as it can. I totally agree – I was an early adopter of the pro series (my first Logic is Revision 0. You will need to tweak it for which analog channels to edit, and it assumes only a Pro 16 device. Compatible with Windows, macOS, and Linux. 80. you can swap out the Saleae VID/PID pair for the USBee AX "Hello, we purchased this logic pro 16 intending to log the value of an 8 bit microcontroller port over time. You may want to back it up first so you can go back to factory default. Thanks for a great product. (I used to do this with picoscope but I need 6 analog data streams for this I currently alternate between two different logic analyzers: a Saleae Logic Pro 8, and a no-name 16 channel device. 00 (used) and the Logic Pro 16 at £819. I tryed the old software and no such limit is enforced. so setting advanced What Is the Difference between Logic/Logic16 (Gen1) and Logic 8/Pro 8/Pro 16 (Gen2)? Recommended USB 3. Logic measuring instruments pdf manual download. Saleae Logic Pro 16 Desktop Organizer thingiverse. Overview. The Noname Saleae Logic clone is USB-based logic analyzer with 8-channel and up to 24MHz sample-rate. Async serial communication is a very generic term that means any data that is transmitted serially (i. More. Logic Does Not Connect over USB 3. 0 Logic analyzers (Logic Pro 8 and Logic Pro 16) via a USB 2. Can you let me know what the maximum input voltage is on the analog channels. 0 host controller drivers. They're both invaluable tools for my development projects. FPGA: Actel A3P125 2. This is called the decimation filter. 5GB of memory buffer size on a Logic Pro 16. The 2nd Generation of Saleae products (Logic 4, Logic 8, Logic Pro 8, & Logic Pro 16) use calibration data generated at Saleae to display accurate AC and DC values. zip link for 1. So similar that the Saleae software worked with it ages ago. This model doesn’t have the ability to enable/disable channels. so for Linux, or . The Saleae Logic 16 Pro is a compact and powerful logic analyzer that can record digital and analog on 16 channels simultaneously. Device Calibration. The following accessories and instructions apply to the following Saleae Logic products - Logic 4, Logic 8, Logic Pro 8, and Logic Pro 16. 1 Parts. I chose this LA over the Saleae due to the big price difference - LA5016 was £131. This arrow should point up (GND), and the signal wires are labeled 0-7 (repeated if you have the Logic Pro 16). Instead, you can hide/show the channels. Over the last 3 nights, 1st night it worked and was still logging when I came in. 5MS/s respectively. It is not installed (rollback is in progress, it was possible to disable rollback with the keys in the registry, because periodically it is necessary to analyze other people’s results), and the device driver does not work normally (refusal to install the driver, Saleae Support. Supported Voltages. Also for: Logic16, Logic 4, Logic pro 16, Saleae001, Saleae009, Sal-00109, Sal-00111, Sal-00112, Sal-00110, Sal-00113, Sal-00114, Sal-00115, Sal-00116, Logic pro 8, Logic 8. $ sigrok-fwextract-saleae-logic16 Logic saved 5214 bytes to saleae-logic16-fx2. Example USB 1. What is the maximum current draw from USB for the Logic Pro 16 ? That is, with the maximum sample rate, all channels operating, etc. In the event you record SPI data and there is no valid enable signal, simply change the "Enable" channel in the SPI analyzer settings to "None" as shown here: Solving Alignment Issues. I am aware of the support articles: “In addition to the hardware AA filter, there is a digital-analog filter that engages for sample rates lower than the advertised sample rate. with the student discount, it would cost about 600 USD after shipping. I have uploaded the latest software for the 16 port saleae logic analyzer. - anno73/Saleae-Logic16-Clone After that when I select "Saleae Logic 16" from driver. I verify both speed, acceleration and motor current. This arrow should point up (same side as the Saleae logo) and to the left (the side with the ‘S’ in Saleae). Astute readers may have noticed that we’ve skipped releases 2. As long as the latest Logic software is used, your Logic hardware will continue to run on the latest firmware. dylib for MacOS) that will be loaded by the Logic software as a plugin. Both Pro 8 and Pro 16 could record single I/O mode at that speed by ignoring either the alert or reset channel. Expand the section "Universal Serial Bus controllers" and check for "Saleae Logic X USB Logic Analyzer" where "X" is the specific product version (4, 8, Pro 8, Pro 16, etc. 1. At the moment, I'm only doing basic FPGA stuff at only a few MHz, but I hope I could get something that which can be used in a long run. Once added, the protocol can be displayed in binary, decimal, hexadecimal, or ASCII, and information is shown Saleae Support. Any use case information you can add in the I bought a MCU123 USBee AX Pro clone on dx. clone windows-10 logic-analyzer sigrok zadig saleae-logic pulseview sigrok-cli Resources. The Saleae Logic Pro 16USB Logic Analyzer is a channel logic analyzer with each input dual purposed for analog data recording. saleae-logic-clone-16 (Custom) By gdevic November 22, 2013 November 22, 2013 Full size is 1600 × 1067 pixels. Installation. , or perhaps some other pin connected to the logic No. It operates by sampling a How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. 00V for continuous operation. Does one of you know more about this? All Saleae devices with analog inputs have fixed analog voltage range. See Saleae Logic16/Info for more details (such as lsusb -v output) about the device. All other Saleae devices had an internal resistance to ground. The new Logic 8 is significantly more advanced than the original Logic device. Saleae Support; Orders & Shipping In case you would like us to provide a standalone version of our Logic 2 app that is immediately available for download, feel free to . Such as SPI or UART or I2C is input analyzer. so. The device connects to a PC over USB and uses the Saleae Logic Software to record and view digital and analog signals. It is labelled and sold as a Saleae Logic16 clone, and comes with "modified" Saleae Logic software on a CD-ROM. Bookmark the permalink. bitstream Copy these files to the directory where your libsigrok The Saleae Logic software includes a protocol decoder to read clocked (synchronous) parallel bus data. My initial instinct was query the slave device as I wrote this slave firmware running on ATtiny816. Saleae Logic analyzer clone, 16 channels. Triggers, decoding, interface setup, and just about every other aspect is so much more advanced. Software Extensions Expand the section "Universal Serial Bus controllers" and check for "Saleae Logic X USB Logic Analyzer" where "X" is the specific product version (4, 8, Pro 8, Pro 16, etc. csv-file and then reading it back from disk, which is pretty tedious. I²C EEPROM: Atmel 24C02N 4. 1 (XCRYPT_2. - anno73/Saleae-Logic16-Clone How I got my Saleae Logic 16 clone to work with sigrok Pulseview on Windows 10. pvqmp gxxwjzc wcgzk qldlx oakvx cznrws dzxyq lyl vtpmb heyvdy